content loaded
419 Image 1

KANE KANE419 100A 1000V TRUE-RMS INDUSTRIAL CLAMP METER

MFR Part #: 419
SKU #: 1689213
Brand: Kane
UEi TEST INSTRUMENTS™ 419 True RMS Industrial Clamp Meter, 1000 V, 1000 A, 40 MOhm, LCD Display
2 Year Limited
ATL57 Test Leads, AAC3 Alligator Clips, (2) AAA Batteries, AC519 Pouch/Case and Manual
For measure linear electrical loads, control voltage or system board voltage checks, circuit continuity or specified resistance, motor run or start faults, quick check of live wires, diode test malfunctions/ unbroken paths and motor inrush applications
CAT IV 600 V|cULus Listed|ETL Listed|RoHS Compliant

UEi TEST INSTRUMENTS™ True RMS Industrial Clamp Meter, 1000 V, 1000 A, 40 MOhm Resistance, 4000, LCD Display, AC Current Accuracy: +/-2.5%, +/-1.5%, Voltage Accuracy: +/-2%, +/-0.5%, +/-0.8%, CAT IV 600 V, 32 to 104 deg F Operating Temperature, 2000 uF, +/-3.5 % Capacitance Accuracy, DC Current Accuracy: +/-2.5%, +/- 1.5%, 80 % Humidity Rating, +/-1 % Resistance Accuracy, 0.1 mV, 1 mV, 10 mV, 100 mV, 1 V, 0.1 Ohm, 1 Ohm, 10 Ohm, 100 Ohm, 1 kOhm, 10 kOhm, 0.01 nF, 0.1 nF, 0.001 uF, 0.01 uF, 1 uF, 0.1 uA, 1 uA, 0.01 A, 0.1 A, 1 A Resolution, 10.6 x 2.5 x 1.5 in

Product Details

UEi TEST INSTRUMENTS™ True RMS Industrial Clamp Meter, 1000 V, 1000 A, 40 MOhm Resistance, 4000, LCD Display, AC Current Accuracy: +/-2.5%, +/-1.5%, Voltage Accuracy: +/-2%, +/-0.5%, +/-0.8%, CAT IV 600 V, 32 to 104 deg F Operating Temperature, 2000 uF, +/-3.5 % Capacitance Accuracy, DC Current Accuracy: +/-2.5%, +/- 1.5%, 80 % Humidity Rating, +/-1 % Resistance Accuracy, 0.1 mV, 1 mV, 10 mV, 100 mV, 1 V, 0.1 Ohm, 1 Ohm, 10 Ohm, 100 Ohm, 1 kOhm, 10 kOhm, 0.01 nF, 0.1 nF, 0.001 uF, 0.01 uF, 1 uF, 0.1 uA, 1 uA, 0.01 A, 0.1 A, 1 A Resolution, 10.6 x 2.5 x 1.5 in

Attributes

Dimensions: 10.6 x 2.5 x 1.5 in
Display Type: LCD
Resistance: 40 MOhm
AC Current Accuracy: +/-2.5%, +/-1.5%
Amperage Rating: 1000 A
Capacitance: 2000 uF
Capacitance Accuracy: +/-3.5 %
Counts: 4000
DC Current Accuracy: +/-2.5%, +/- 1.5%
Humidity Rating: 80 %
Operating Temperature: 32 to 104 deg F
Resistance Accuracy: +/-1 %
Resolution: 0.1 mV, 1 mV, 10 mV, 100 mV, 1 V, 0.1 Ohm, 1 Ohm, 10 Ohm, 100 Ohm, 1 kOhm, 10 kOhm, 0.01 nF, 0.1 nF, 0.001 uF, 0.01 uF, 1 uF, 0.1 uA, 1 uA, 0.01 A, 0.1 A, 1 A
Safety Rating: CAT IV 600 V
Voltage Accuracy: +/-2%, +/-0.5%, +/-0.8%
Voltage Rating: 1000 V

Features

  • True RMS
  • LRA Inrush current measurement
  • Data hold
  • Min/Max
  • Relative/DC A Zero mode
  • High contrast backlit display
  • Auto/ Manual ranging
  • Magnetic mount
  • Bargraph
  • Auto power off
  • 2-Year limited warranty