content loaded
GOODMAN GCES961205DN Image 1

GOODMAN GCES961205DN FER CF FURNACE

MFR Part #: GCES961205DN
SKU #: 3231948
Brand: Goodman®
UPC: 978726
Goodman® GCES961205DN Gas Furnace, 5 ton, 120000 Btu/hr Input BTU, 115 VAC, 2000 cfm, 1 hp at 1075 rpm, 96 % AFUE
10 Year Parts and Unit Replacement, Limited Lifetime on Heat Exchanger
AHRI Certified, ETL Listed, ISO 9001 and 14001

Goodman® Gas Furnace, Model: GCES96, Input BTU Rating: 120000 Btu/hr, 115 VAC, 16.93 A, 2000 cfm, 1 hp at 1075 rpm, 96 % AFUE Rating, 1 ph Phase, 60 Hz, Downflow/Horizontal, 1/2 in FPT Gas Connection, Low Nox Fuel, 6 Burners, 5 Speed, Blower Size: 11 in Dia x 11 in W, 24-1/2 in W x 28-7/8 in D x 34-1/2 in H Cabinet, Downflow/Horizontal Motor, 3 in Vent, 20 A Fuse Rating, Tonnage: 5 ton, Heavy Gauge Steel, 45 to 75 deg F Temperature Rise

Product Details

Goodman® Gas Furnace, Model: GCES96, Input BTU Rating: 120000 Btu/hr, 115 VAC, 16.93 A, 2000 cfm, 1 hp at 1075 rpm, 96 % AFUE Rating, 1 ph Phase, 60 Hz, Downflow/Horizontal, 1/2 in FPT Gas Connection, Low Nox Fuel, 6 Burners, 5 Speed, Blower Size: 11 in Dia x 11 in W, 24-1/2 in W x 28-7/8 in D x 34-1/2 in H Cabinet, Downflow/Horizontal Motor, 3 in Vent, 20 A Fuse Rating, Tonnage: 5 ton, Heavy Gauge Steel, 45 to 75 deg F Temperature Rise

Attributes

AFUE Rating: 96 %
Configuration: Downflow/Horizontal
Model: GCES96
Motor Type: Downflow/Horizontal
Tonnage: 5 ton
Amperage Rating: 16.93 A
Blower Size: 11 in Dia x 11 in W
Cabinet Dimensions: 24-1/2 in W x 28-7/8 in D x 34-1/2 in H
CFM Rating: 2000 cfm
Connection Type: 1/2 in FPT Gas
Frequency Rating: 60 Hz
Fuel Type: Low Nox
Fuse Rating: 20 A
HP Rating: 1 hp at 1075 rpm
Input BTU Rating: 120000 Btu/hr
Material: Heavy Gauge Steel
Number of Burners: 6
Number of Speeds: 5
Phase: 1 ph
Temperature Rise: 45 to 75 deg F
Vent Size: 3 in
Voltage Rating: 115 VAC

Features

  • Heavy-duty aluminized steel tubular heat exchanger
  • Stainless steel secondary heat exchanger
  • Single-stage gas valve
  • Durable silicon nitride igniter
  • Quiet, single-speed draft induced
  • Self-diagnostic control board with constant memory fault code history output to a LED
  • All models comply with California 40 ng/J Low NOx emissions standard
  • Convenient left or right connection for gas and electrical service
  • Cabinet air leakage (QLeak) less than 2%
  • Heavy-gauge steel cabinet with durable finish
  • Fully insulated heat exchanger and blower section
  • Airtight solid bottom for side return with easy cut tabs for effortless removal in bottom air inlet applications